<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://wiki.seasons4.net/mediawiki/index.php?action=history&amp;feed=atom&amp;title=VFD_Compressors_with_Electronic_Expansion_Valves</id>
	<title>VFD Compressors with Electronic Expansion Valves - Revision history</title>
	<link rel="self" type="application/atom+xml" href="http://wiki.seasons4.net/mediawiki/index.php?action=history&amp;feed=atom&amp;title=VFD_Compressors_with_Electronic_Expansion_Valves"/>
	<link rel="alternate" type="text/html" href="http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;action=history"/>
	<updated>2026-08-07T01:51:44Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.39.17</generator>
	<entry>
		<id>http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=176&amp;oldid=prev</id>
		<title>Timm at 13:25, 3 December 2021</title>
		<link rel="alternate" type="text/html" href="http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=176&amp;oldid=prev"/>
		<updated>2021-12-03T13:25:32Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:25, 3 December 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 11:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 11:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The EEV selections do NOT have any over capacity built in to the Sporlan program like the TXV’s, so it is recommend that EEVs be selected for 90% maximum rating. It is important to keep in mind that you do not have to be as concerned with the valve being “oversized” for EEVs as the valve’s control is consistent through the range of operation.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The EEV selections do NOT have any over capacity built in to the Sporlan program like the TXV’s, so it is recommend that EEVs be selected for 90% maximum rating. It is important to keep in mind that you do not have to be as concerned with the valve being “oversized” for EEVs as the valve’s control is consistent through the range of operation.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[https://sporlanonline.com/literature/100/ev/100-20%20Electric%20Expansion%20Valves.pdf https://sporlanonline.com/literature/100/ev/100-20%20Electric%20Expansion%20Valves.pdf]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;

&lt;!-- diff cache key my_wiki:diff:wikidiff2:1.12:old-175:rev-176:1.13.0 --&gt;
&lt;/table&gt;</summary>
		<author><name>Timm</name></author>
	</entry>
	<entry>
		<id>http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=175&amp;oldid=prev</id>
		<title>Timm at 13:22, 3 December 2021</title>
		<link rel="alternate" type="text/html" href="http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=175&amp;oldid=prev"/>
		<updated>2021-12-03T13:22:17Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:22, 3 December 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 8:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 8:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Effective immediately, all circuits with a Copeland ZPV variable speed compressor will have an electronic expansion valve for improved superheat control. Sales has been notified to include this on all factory orders, but if they have missed it, please make sure to have them add it to the factory order. Only the ZPV circuit will get an EEV, unless specified otherwise in the factory order.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Effective immediately, all circuits with a Copeland ZPV variable speed compressor will have an electronic expansion valve for improved superheat control. Sales has been notified to include this on all factory orders, but if they have missed it, please make sure to have them add it to the factory order. Only the ZPV circuit will get an EEV, unless specified otherwise in the factory order.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;u&amp;gt;EEV Selection:&amp;lt;/u&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The EEV selections do NOT have any over capacity built in to the Sporlan program like the TXV’s, so it is recommend that EEVs be selected for 90% maximum rating. It is important to keep in mind that you do not have to be as concerned with the valve being “oversized” for EEVs as the valve’s control is consistent through the range of operation.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;

&lt;!-- diff cache key my_wiki:diff:wikidiff2:1.12:old-72:rev-175:1.13.0 --&gt;
&lt;/table&gt;</summary>
		<author><name>Timm</name></author>
	</entry>
	<entry>
		<id>http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=72&amp;oldid=prev</id>
		<title>Timm at 21:11, 31 January 2020</title>
		<link rel="alternate" type="text/html" href="http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=72&amp;oldid=prev"/>
		<updated>2020-01-31T21:11:23Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:11, 31 January 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Effective immediately, all circuits with a Copeland ZPV variable speed compressor will have an electronic expansion valve for improved superheat control. Sales has been notified to include this on all factory orders, but if they have missed it, please make sure to have them add it to the factory order. Only the ZPV circuit will get an EEV, unless specified otherwise in the factory order.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Effective immediately, all circuits with a Copeland ZPV variable speed compressor will have an electronic expansion valve for improved superheat control. Sales has been notified to include this on all factory orders, but if they have missed it, please make sure to have them add it to the factory order. Only the ZPV circuit will get an EEV, unless specified otherwise in the factory order.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;amp;nbsp;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;

&lt;!-- diff cache key my_wiki:diff:wikidiff2:1.12:old-71:rev-72:1.13.0 --&gt;
&lt;/table&gt;</summary>
		<author><name>Timm</name></author>
	</entry>
	<entry>
		<id>http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=71&amp;oldid=prev</id>
		<title>Timm: Created page with &quot;&lt;p style=&quot;text-align: right;&quot;&gt;Return to Engineering Main Menu&lt;/p&gt;  &lt;u&gt;Email from Clay Brown to Engineering on 1/22/20&amp;nbsp;&lt;/u&gt;  &#039;&#039;&#039;Subject:&#039;&#039;&#039; Electronic Expa...&quot;</title>
		<link rel="alternate" type="text/html" href="http://wiki.seasons4.net/mediawiki/index.php?title=VFD_Compressors_with_Electronic_Expansion_Valves&amp;diff=71&amp;oldid=prev"/>
		<updated>2020-01-31T21:10:51Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;&amp;lt;p style=&amp;quot;text-align: right;&amp;quot;&amp;gt;Return to &lt;a href=&quot;/mediawiki/index.php/Engineering&quot; title=&quot;Engineering&quot;&gt;Engineering Main Menu&lt;/a&gt;&amp;lt;/p&amp;gt;  &amp;lt;u&amp;gt;Email from Clay Brown to Engineering on 1/22/20 &amp;lt;/u&amp;gt;  &amp;#039;&amp;#039;&amp;#039;Subject:&amp;#039;&amp;#039;&amp;#039; Electronic Expa...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;lt;p style=&amp;quot;text-align: right;&amp;quot;&amp;gt;Return to [[Engineering|Engineering Main Menu]]&amp;lt;/p&amp;gt; &lt;br /&gt;
&amp;lt;u&amp;gt;Email from Clay Brown to Engineering on 1/22/20&amp;amp;nbsp;&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Subject:&amp;#039;&amp;#039;&amp;#039; Electronic Expansion Valves for Copeland ZPV compressors&lt;br /&gt;
&lt;br /&gt;
&amp;amp;nbsp;&lt;br /&gt;
&lt;br /&gt;
Effective immediately, all circuits with a Copeland ZPV variable speed compressor will have an electronic expansion valve for improved superheat control. Sales has been notified to include this on all factory orders, but if they have missed it, please make sure to have them add it to the factory order. Only the ZPV circuit will get an EEV, unless specified otherwise in the factory order.&lt;br /&gt;
&lt;br /&gt;
&amp;amp;nbsp;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Email from Clay Brown to Sales Departments on 1/8/20&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Subject:&amp;#039;&amp;#039;&amp;#039; Electronic Expansion Valves for Copeland ZPV compressors&lt;br /&gt;
&lt;br /&gt;
&amp;amp;nbsp;&lt;br /&gt;
&lt;br /&gt;
The first group of teardown reports on the Copeland ZPV compressors show lack of lubrication as the suspected cause of failure, but the several most recent teardowns indicate dilution/washout/slugging as the mode of failure. The end result of both of these failure modes is similar, but the latter shows evidence of liquid back to the compressor. Liquid back to the compressor indicates a loss of superheat control.&lt;br /&gt;
&lt;br /&gt;
To provide better superheat control across the wide operating range of the ZPV compressors, all refrigerant circuits with a ZPV compressor will be provided with an electronic expansion valve going forward. These valves more expensive than a thermostatic expansion valve, but the data suggests that the EEV is more appropriate choice to prevent liquid refrigerant back to the compressor. Unless required by the project specifications, standard single stage, digital or tandem compressors will have a standard thermostatic expansion valve.&lt;br /&gt;
&lt;br /&gt;
Please make sure that this is included in all future quotes and factory orders for units with ZPV variable speed compressors.&lt;/div&gt;</summary>
		<author><name>Timm</name></author>
	</entry>
</feed>